Basic Red 28

Introduction

In the January/February 1995 issue of the Journal of Forensic Identification (volume 45, number 1), Williams D. Mazzella and Christopher J. Lennard of the Institut de Police Scientifique et de Criminologie in Lausanne-Dorigny, Switzerland, discuss the uses of Basic Red 28 and how it compares to Rhodamine 6G, Basic Yellow 40 and Styryl 7. They concluded that Basic Red 28 has a Stokes Shift three times that of Rhodamine 6G (90 nm versus 30 nm). It can be mixed with a solution of Basic Yellow 40 to provide a wider range (145 nm) of fluorescence.

Safety

As with all chemicals, always read the MSDS (material safety data sheet) to learn about the safe handling and health hazards of each chemical. With Basic Red 28, it is recommended that rubber gloves and safety glasses be worn. When combined with any of the solvents listed below, the solution should be mixed and used in a fume hood. When examining the evidence with a light source, wear protective goggles. Be familiar with the light source you are using and know which goggles to wear under all circumstances.

Mixing Instructions

Stock Solution: Dissolve 0.2 grams of Basic Red 28 in 60 ml of propanol and then add 40 ml acetonitrile.

Working Solution: Dilute 5 ml of the stock solution with petroleum ether to make 100 ml.

Mix and use these solutions in a fume hood. Store the liquids in dark brown glass jars with tight-fitting lids.

Application

In a fume hood, apply the Basic Red 28 solution by submerging the evidence in a tray or container. "Washing" the solution over the surface using a chemical wash bottle can also be done. Catch the runoff solution in a clean tray and use it again. DO NOT SPRAY THIS SOLUTION. After the item has dried, rinse it with distilled water to remove any background staining. Allow the item to air-dry before examining with a light source.

Modified Solution

A modified solution can be made using a combination of a solution of Basic Yellow 40 and a solution of Basic Red 28. Stock Solution of Basic Yellow 40: Dissolve 0.1 g of the powder Basic Yellow 40 in 60 ml of propanol and add 40 ml acetonitrile.

Working Combination Solution: Mix 3 ml of Basic Yellow 40 Stock Solution and 2 ml of Basic Red 28 Stock Solution. Dilute this mixture in petroleum ether to make 100 ml of solution.

Glue Fuming

Before using Basic Red 28, it is necessary to glue fume the piece of evidence. It is recommended to underfume rather than overfume. If heavy white residue is present on the background surface or heavy white latent prints are developed, the Basic Red 28 solution may stain the entire surface and the latent prints will appear as bright glowing globs with no ridge detail when illuminated with a light source. The use of fast-acting, chemical catalysts or accelerator pads is not recommended, as the process can develop heavy, white residue before the reaction can be stopped.

Place a few drops of liquid glue or place a Hard Evidence™ Pouch in a closed container, such as a fish tank, with the evidence and a cup of warm water. Allow the evidence to remain about ten minutes before checking. To check the progress of the fuming without opening the lid of the fish tank, place a black latent print backing card in the tank with test prints on it. When these test prints are just becoming visible, remove the evidence from the tank to stop the process.

Fuming under vacuum with a Coleman Vacu-Print™ will help to eliminate the problems associated with overfuming. Vacuum technology for glue fuming is relatively new. This method will develop latent prints without excessive residue coating the surface of the evidence, and it will be easier to handle the evidence.

Because fuming under vacuum leaves no residue buildup on the evidence, dye-staining for fluorescent examination is more effective. Dyes such as Basic Red 28, Rhodamine 6G and Ardrox adhere to the glue residue on the item. When there is excessive buildup of the glue residue, the dye stains all of it, causing the entire surface to fluoresce, perhaps obscuring ridge detail. With a vacuum process, items of evidence, such as garbage bags, do not have to be opened up. The fumes will coat all of the surfaces. Also, items such as soda cans, screwdrivers and handguns can be placed inside the chamber with the items touching each other. It is not necessary to leave space between each item. For additional information on the Coleman Vacu-Print™ vacuum fuming chamber and glue fuming processes, see our technical notes on glue fuming and the Coleman Vacu-Print™.

Photography

To photograph the fluorescent-developed latent prints, duplicate the arrangement by which the best contrast was viewed with the eye. Use the wavelength, the color of the viewing goggles and the angle of the light source to obtain the best photograph. Include a fluorescent scale in the photograph. Using a fine-grain black and white film with a medium ƒ-stop (ƒ/8 or ƒ/11) will give a photograph showing highly-defined ridge details. The ridges will be white and the background will be dark in the resulting photograph. To reverse the color of fluorescent-developed latent prints, take the photographs using slide film, such as Polaroid PolaPan, to see the results in just a few minutes. Print the slide film on regular black and white photo paper and see the ridges dark and the background light. For additional information on photography of fluorescent latent prints, see our technical note on fluorescent photography.

Additional Reading

Advances in Fingerprint Technology edited by Dr. Henry Lee and Dr. R. E. Gaensslen
Friction Ridge Skin: Comparison and Identification of Fingerprints by James F. Cowger
Manual of Fingerprint Development Techniques by the British Home Office
Fingerprint Detection by Fluorescence Examination by the British Home Office, second edition
An Introduction to Lasers, Forensic Lights and Fluorescent Fingerprint Detection Techniques by Dr. E. Roland Menzel

Ordering Information

Catalog No. 1-0075 Basic Red 28, 10 grams
Catalog No. 1-0044 Basic Yellow 40, 25 grams
Catalog No. 6-3847 Adhesive Fluorescent Scales, 2 in-50 mm, pack of 50
Catalog No. 6-3816 6 inch Fluorescent Scales, cardstock, pack of 10
Catalog No. 6-3885 INCH "L" Shaped Scale, Fluorescent, cardstock, pack of 5
Catalog No. 8-5015 HOME OFFICE/Manual of Fingerprint Development Techniques, 2nd edition
Catalog No. 8-5039 HOME OFFICE/Fingerprint Detection by Fluorescence Examination
Catalog No. 8-5041 LEE/Advances in Fingerprint Technology
Catalog No. 8-5043 MENZEL/Intro to Lasers, Forensic Lights & Fluorescent Fingerprint Detection

   

Download the technical note in .pdf format (Adobe Acrobat Reader required).



Comments or Questions:


Introduction

The goal of latent print examiners and technicians is to discover and collect latent prints by various means. The ultimate goal is to identify those latent prints to the person responsible for the criminal act and prosecute them to the fullest extent of the law. Some of these means to develop latent prints include processing evidence and other surfaces using powders, chemicals and lighting techniques. The purpose of this booklet is to provide a resource of information about latent print processing techniques. This booklet does not contain every process available and does not claim to be all inclusive of all variations of processes. The information has been collected from various sources.

Caution

This booklet contains descriptions of processes utilizing chemicals or combinations of chemicals which may be hazardous to the user's health. It is strongly recommended that proper precautions be taken when using hazardous chemicals or combinations thereof. Safety equipment needed may include fume hoods, gloves, protective clothing, safety goggles, splash shields or respirators. It may be necessary to store these chemicals in specific containers or cabinets. It is the user's responsibility to know and use the proper and adequate safety equipment required the various chemicals listed.

Disclaimer

Lightning Powder Company, Inc. assumes no responsibility for the use or misuse of any of the chemicals, procedures, methods of ideas described herein resulting in injury and/or damage to persons or property.
Copyright © 2005 Lightning Powder Company, Inc.
The material contained in and displayed by this Web site may be reproduced with acknowledgment of its source.

 

Lightning Powder Company, Inc.
13386 International Parkway, Jacksonville, FL 32218
Tel: (800) 852-0300 or (904) 485-1836
Fax: (800) 588-0399 or (904) 741-5407
Send us an e-mail


© 2007 BAE Systems All rights reserved.